E-JIN Heating System Co., Ltd.

Case of Installation

S.G.W상세보기

  • CategoryPit Type Heat Treatment Furnace
  • ClientS.G.W
  • ProjectJanuary, 2016 / Vacuum Purge Type Pressure Gas Nitriding Furnace Installed -1EA

본문

◆ Equipment Specifications ◆

Power

380V × 3P × 66Kw ( 2Part )

Working Temperature

550℃ / Max. 700℃

Max. Work Zone Dimensions

Ø700 × 900H

Loading Weight

0.6 ton / ch

Input Gas

Ammonia(NH3), Nitrogen(N₂),

Carbon Dioxide(CO2)

   

Inner Pot Cooling System

Vacuum Type Cooling Blower

/ 3Way Heat Exchanger

Outer Pot Cooling System

2 Suction Blowers /

Automatic On-off Exhaust Port

Cooling Process Time

Processing 1ton,

keeping the heating at 550~580℃

Within 4hours,

cooling under 100℃ completed

Type of Insulation

Ceramic Wool + Firebrick

 