Tempering Furnace has the convection currents stirring device(fan) installed to maintain regular temperature distribution and easy convection current inside of the furnace. It's designed optimal according to the service temperature.






| Power | 60kw (1Part) | ![]() |
|---|---|---|
| Working Temperature | Max. 700℃ | |
| Work Zone Dimensions | 700W×600H×1,200D | |
| Loading Weight | 600kg/ch | |
| Temperature Distribution | ±7℃ | |
| Use | Automobile parts |
| Power | 70kw (1Part) | ![]() |
|---|---|---|
| Working Temperature | Max. 700℃ | |
| Work Zone Dimensions | 700W×700H×1,250D | |
| Loading Weight | 1 ton/ch | |
| Temperature Distribution | ±5℃ | |
| Use | Defense industry materials |
| Power | 40kw (1Part) | ![]() |
|---|---|---|
| Working Temperature | Max. 300℃ | |
| Work Zone Dimensions | 500W×550H×1,000D | |
| Loading Weight | 300kg/ch | |
| Temperature Distribution | ±3.5℃ | |
| Use | High-frequency automobile parts |
| Power | 100kw (6Part) | ![]() |
|---|---|---|
| Working Temperature | Max. 300℃ | |
| Work Zone Dimensions | 500W×500H×6,000D | |
| Loading Weight | 4 ton/ch | |
| Temperature Distribution | ±5℃ | |
| Use | LM Guide / Ball screw |
| Power | 120kw (4Part) | ![]() |
|---|---|---|
| Working Temperature | Max. 500℃ | |
| Work Zone Dimensions | 700W×100H×12,200D | |
| Loading Weight | 500kg/ch | |
| Temperature Distribution | ±7℃ | |
| Use | Wiper blades |
| Power | 90kw (4Part) | ![]() |
|---|---|---|
| Working Temperature | Max. 300℃ | |
| Work Zone Dimensions | 900W×120H×4,900D | |
| Loading Weight | 500kg/ch | |
| Temperature Distribution | ±7℃ | |
| Use | High-frequency automobile parts |