◆ Equipment Specifications ◆ | |
Power | 220V × 3P × 200Kw Max. 250Kw (Single-Phase 3Part) |
Working Temperature | 1,050 ~ 1,200℃ / Max : 1,300℃ |
Max. Work Zone Dimensions | 700W × 700H × 1,200D |
Loading Weight | 700 Kg / ch |
Input Gas | Nitrogen ( N₂ ) |
Insulation | Graphite Felt + Graphite Foil |
Cooling Blower | Turbo Type Ø500 × 260H |
Max. Vacuum Level | 5.0×10-3 Torr |
Cooling Water Piping | SUS 304 / Brass |
◆ Composition of Equipment ◆ | |
Vacuum Heat Treatment Furnace | 1EA |
Rotary Pump & Oil Mist Collector | 1EA |
Booster Pump | 1EA |
Fin Type Copper Heat Exchanger | 3EA |
Motorized Lift for All Directions | 2EA |
Cooling Blower | 1EA |
Electric Control Panel | 1Sheet |
N2 Sub Tank ( 3㎥ ) | 1EA |